Etrel AC Charger

Supported devices: Inch Pro, Inch Duo.

1

Startup and connection

Once all wiring is complete, switch on the charger.

  • Wait for Green: The green LED flashes during startup. Wait until it turns solid green; the charger is now ready for use. This LED is located just above the charger display.

  • Open Web Interface: Connect your laptop to the same network as the charger. Enter the IP address (found on the sticker inside the maintenance door) into your browser.

Tip: Can't find the IP address? Press and hold the small reset button (inside the small door on the top right) until you hear a beep. This accesses the charging station settings. Navigate to the correct sub-menu on the screen to view the current IP address.

2

Settings and Modbus

Log in and go to the configuration page.

  • Email: root@etrel.com

  • Password: toor

  • IP Configuration: Preferably set a static IP address within the same range as the Voltmaster Controller.

  • Enable Modbus: Go to the settings menu and activate Modbus TCP.

    • Settings: Unit ID = 1, Port = 502.

  • Firewall: Ensure Port 502 and Subnet 255.255.255.0 are open.

3

Restart the charger

Important: After changing the network or Modbus settings, you must restart the charging station to ensure the new configuration takes effect.

  • Action: Reboot the charger via the web interface or by power cycling the unit.

  • Wait: Wait until the LED above the display turns solid green again.

4

Safety check and completion

  • Protection: Verify that the Residual Current Device (RCD) and Miniature Circuit Breaker (MCB) are active.

Note: For Etrel INCH models without built-in protection, these must be installed externally in the main distribution board.

  • LED Status Check (above Display):

    • Green: Available.

    • Flashing Blue: Charging in progress.

    • Red: Error (inspection required).