# Sungrow

Sungrow is a global leader in solar inverter and energy storage solutions. Within our EMS, we support a wide range of Sungrow inverters for monitoring, control, and energy management purposes. This integration enables centralized management of production data, energy consumption, and smart control functionalities through our EMS platform.

The following Sungrow devices are compatible with and supported by our EMS for communication and integration:

#### RT Series

* SG3.0RT
* SG4.0RT
* SG5.0RT
* SG6.0RT
* SG7.0RT
* SG8.0RT
* SG10RT
* SG12RT
* SG15RT
* SG17RT
* SG20RT

#### KTL-M Series

* SG5KTL-MT
* SG6KTL-MT
* SG8KTL-M
* SG10KTL-M
* SG10KTL-MT
* SG12KTL-M
* SG15KTL-M
* SG17KTL-M
* SG20KTL-M
* SG30KTL-M
* SG30KTL-M-V31
* SG33KTL-M
* SG36KTL-M
* SG50KTL-M-20
* SG80KTL-M

#### CX Series

* SG25CX-SA
* SG30CX
* SG33CX
* SG40CX-P2
* SG50CX
* SG75CX
* SG100CX
* SG100CX-JP
* SG110CX
* SG36CX-US
* SG60CX-US

#### KU / KTL Series

* SG60KU
* SG60KU-M
* SG60KTL
* G80KTL
* SG80KTL-20

#### HV / BF Series

* SG80HV
* SG80BF
* SG85BF
* SG110HV-M
* SG111HV
* SG125HV
* SG125HV-20

#### HX / TX Series

* SG136TX
* SG225HX
* SG250HX
* SG250HX-IN
* SG250HX-US

#### Other Supported Models

* SG33K3J
* SG34KJ
* SG49K5J
* LP\_P34KSG
* Logger1000B

## Physical Connection

### Ethernet Connection

For a correct Ethernet installation, follow the standard Ethernet cabling guidelines.

## Network Configuration

### Ethernet Configuration

To configure the inverter for Ethernet communication:

1. Open the inverter display interface
2. Navigate to:
   * **Settings → Communication Parameters**
3. Enable **MODBUS-TCP**
4. Set the communication port:
   * **Default Port: 502**
5. Configure:
   * DHCP, or
   * A static IP address depending on your network requirements

***

## Device Configuration

### Enable Modbus Communication

1. Open the inverter LCD display
2. Navigate to:
   * **Settings → Communication Parameters**
3. Configure the following settings:

| Parameter      | Value                        |
| -------------- | ---------------------------- |
| Protocol       | MODBUS                       |
| Device Address | Unique address between 1–247 |

### Modbus TCP Settings

| Parameter  | Value                              |
| ---------- | ---------------------------------- |
| MODBUS-TCP | Enabled                            |
| Port       | 502 (default)                      |
| IP Address | According to network configuration |

{% hint style="warning" %}
Important issue
{% endhint %}

<figure><img src="/files/SXAq8v4oohpakDFnZ2pL" alt=""><figcaption></figcaption></figure>


---

# Agent Instructions: Querying This Documentation

If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter:

```
GET https://docs.voltmasters.io/documentation/device-integrations/pv-inverters/sungrow.md?ask=<question>
```

The question should be specific, self-contained, and written in natural language.
The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.